Skip to main content

XOS Clora R Analyzers


This state-of-the-art technology complies with ASTM D7536 and D4929C and delivers unparalleled accuracy and precision for petroleum and petrochemical applications where simple, quick, and reliable analysis is critical.

Analyze Total Chlorine with Unparalleled Precision

The Clora R compact analyzer measures total chlorine in hydrocarbons such as aromatics, distillates, heavy fuels, crude oils, and water.

Easier to use than ever, Clora 2XP R analyzes total chlorine in liquid hydrocarbons such as aromatics, distillates, heavy fuels, and crude oils, as well as aqueous solutions, while automatically correcting for Sulfur interference.

  • Applications

    Clora R:

    • Total chlorine analysis in petroleum products, biofuels, aromatics, and other chemicals, and water
    • For refineries, petrochemical and additive plants, pipeline terminals, and test laboratories

    Clora 2XP R:

    • Total chlorine analysis from aqueous solutions and aromatic products to heavy fuels and crudes
    • For refineries, petrochemical and additive plants, pipeline terminals, and test laboratories
  • Benefits

    • LIMS integration for data management and transfer
    • Custom sample presets to save data entry time and minimize data entry error on common samples
    • Bar code reader auto fills sample name to reduce data entry time
    • Storage capacity for more than 50,000 measurement results
    • Supports up to 30 calibration curves
    • USB connectivity in front and back for connecting to printer, keyboard, mouse, and memory stick
    • Supports USB and network printers
    • Large, easy-to-remove side panels for easy serviceability
    • Advanced error reporting and diagnostics
  • Downloads

  • Features

    Clora R Analyzer

     
    • LOD: 0.13 mg/kg (ppm) at 300s, 0.09 mg/kg (ppm) at 600s for hydrocarbons, 0.3 mg/kg (ppm) at 300s, 0.2 mg/kg (ppm) at 600s for aqueous samples **
    • Dynamic Range: 0.13 mg/kg (ppm) to 4 wt%
    • Manual sulfur correction to correct for high sulfur interference
    • Easy to use:
      • Intuitive 10-inch touch screen
      • Just plug in and measure
    • Measurement time: 10-999 s
    • Low and high range available:
      • Low range: 0.13 mg/kg (ppm) – 3000 mg/kg (ppm)
      • High range: 0.3 wt% - 4 wt%
    • Extremely low maintenance: no gasses, heating elements, columns, or quartz tubing
    • Traditional XRF sample cups or XOS Accucells – decided at time of order
    • Small footprint
    XOS Clora R Series analyzer

    Clora 2XP R Analyzer

     
    • LOD: 0.1 mg/kg (ppm) at 300s, 0.07 mg/kg (ppm) at 600s in hydrocarbons**
    • Range: 0.1 mg/kg (ppm) – 2 wt%
    • Automatic sulfur correction saves time and improves accuracy and precision on high sulfur samples
    • Easy to use:
      • Intuitive 10-inch touch screen
      • Just plug in and measure
    • Measurement time: 10-999 s
    • Low and high range available:
      • Low range: 0.1 mg/kg (ppm) – 3000 mg/kg (ppm)
      • High range: 0.3 wt% - 2 wt%
    • Low maintenance: no gasses, heating elements, columns, or quartz tubing
    • Traditional 43 mm XRF sample cups
    • Small footprint
    XOS Clora2XP R Series analyzer

     

Da Vinci Laboratory Solutions B.V. - T +31 (0)10 258 1870 - E This email address is being protected from spambots. You need JavaScript enabled to view it.